Product Overview
This Professional Clamp Meter measure both DC and AC with clamp it also has many functions for AC measurements including resistance, HZ%, capacitance and diode test,etc.With mid-size and tear-drop shaped jaw,it is easy to use in crowded cable areas and other tight places
- Double molded housing
- 4000 counts digital display with backlight
- Electronic overload protection
- Auto Power Off and Low Battery indication
- Data Hold function
- DCA Zero function
- AC/DC Current
Data Hold Button
To freeze the LCD meter reading, press the data hold button. The data hold button is located on the left side of the meter (top button). While data hold is active, the HOLD display icon appears on the LCD. Press the data hold button again to return to normal operation.
Note: The HOLD feature will activate when the Backlight is turned on.Press the HOLD key again to exit Hold.
Backlight Button
The backlight function illuminates the display and is used when the ambient light to too low to permit viewing of the displayed readings. Press the button for one second to turn the backlight on and press the button a second time to turn the backlight off.
Manual Ranging
The meter turns on in the autoranging mode.Press the RANGE button to go to manual ranging. Each press of the range button will step to the next range as indicated by the unitsand decimal point location.Press and hold the RANGE button for two seconds to return to autoranging. Manual ranging does not function in the AC Current, Diode and Continuity check functions.
Function |
Range & Resolution |
Accuracy (% of reading) |
DC Current on Clamp |
40.00 ADC |
+ (2.8% + 10 digits) |
400.0 ADC |
+ (2.8 % + 5 digits) |
|
1000 ADC |
+ (3.0 % + 5 digits) |
|
AC Current on Clamp |
40.00 AAC |
+ (3.0% + 10 digits) |
400.0 AAC |
+ (3.0 % + 5 digits) |
|
1000 AAC |
+ (3.0 % + 5 digits) |
|
DC Voltage |
400.0 mVDC |
+ (0.8% + 3 digits) |
4.000 VDC |
+ (1.5% + 3 digits) |
|
40.00 VDC |
||
400.0 VDC |
||
600 VDC |
+ (2.0% + 3 digits) |
|
AC Voltage |
400.0 mVAC |
+ (0.8% + 20 digits) |
4.000 VAC |
+ (1.8% + 5 digits) |
|
40.00 VAC |
||
400.0 VAC |
||
600 VAC |
+ (2.5% + 5 digits) |
|
Resistance |
400.0 O |
+ (1.0% + 4 digits) |
4.000K O |
+ (1.5% + 2 digits) |
|
40.00K O |
||
400.0K O |
||
4.000M O |
+ (2.5% + 3 digits) |
|
40.00M O |
+ (3.5% + 5 digits) |
Capacitance |
40.00nF |
+(5.0% reading + 100 digits) |
400.0nF |
+(3.0% reading + 5 digits) |
|
4.000µF |
+(3.5% reading + 5 digits) |
|
40.00µF |
||
100.0µF |
+(5.0% reading + 5 digits) |
|
Frequency |
5.000Hz |
+(1.5% reading + 5 digits) |
50.00Hz |
+(1.2% reading + 2 digits) Sensitivity: 10Vrms min. |
|
500.0Hz |
||
5.000kHz |
||
50.00kHz |
||
100.0kHz |
||
Duty cycle |
0.5 to 99.0% |
+(1.2% reading + 2 digits) |
Pulse width: 100?s - 100ms, Frequency: 5.000Hz ~ 100.0kHz |
||
Temperature |
-20 to 1000 C |
+(3.0% reading + 5C) |
Type-K (probe accuracy not included) |
-4 to 1832F |
+(3.0% reading + 7F) |
What's In The Box
|